Key takeaways
- Compare the best backflow preventers for home water lines, from RPZ assemblies to vacuum breakers, with sizes, pressure limits and approval listings.
A backflow preventer is a one-job device with serious consequences when it is missing. It sits on a water line and stops polluted water from moving backward into the clean supply when pressure drops or reverses. That backward movement, called backsiphonage or backpressure, can pull irrigation water, fertilizer, boiler chemicals or hose water into the pipes a household drinks from. Most codes require a listed device wherever a cross-connection exists, and many utilities require yearly testing on the larger assemblies.
The five devices below cover the main residential cases: a reduced pressure zone assembly for high hazard lines, a pressure vacuum breaker for sprinkler systems, a double check assembly for lower hazard service lines, a lightweight composite reduced pressure unit, and a small anti-siphon vacuum breaker for hose duty. Each entry sticks to the sizes, pressure limits and listings the maker publishes.
Disclosure: As an Amazon Associate, we earn from qualifying purchases made through links on this page, at no extra cost to you.
How to Choose a Backflow Preventer
Match the device type to the hazard level. Codes divide cross-connections into health hazard and non-health hazard. A reduced pressure zone assembly, often shortened to RPZ, gives the highest protection because a relief valve between two check valves opens and dumps water if either check fouls. It suits chemical feed lines, boilers and any line where contaminants could harm health. A double check valve assembly protects against polluted but non-toxic water. A pressure vacuum breaker protects against backsiphonage only, never backpressure, and is the standard choice for lawn irrigation. A small atmospheric vacuum breaker handles single outlets such as hose bibbs.
Check the listing, not just the shape. A device only satisfies code when it carries the approval your authority requires: ASSE 1013 for reduced pressure assemblies, ASSE 1015 for double check assemblies, ASSE 1020 for pressure vacuum breakers and ASSE 1001 for atmospheric vacuum breakers. Confirm whether your utility also wants USC Foundation approval.
Size the device to the line and the flow. Residential assemblies run from 1/2 inch to 2 inch. Match the nominal pipe size, then check the maker’s flow curve: an undersized assembly drops pressure at peak demand and can chatter, while an oversized one may not seal well at low flow. Note the lay length too, because a replacement is easier when the new body fits the gap.
Plan for testing and drainage. Testable assemblies have test cocks and shutoff valves so a certified tester can verify both checks with a gauge kit. An RPZ also needs a drain nearby, since its relief valve discharges water when it fouls. Leave clearance below and around the body.
Respect the installation rules for vacuum breakers. A pressure vacuum breaker must sit at least 12 inches above the highest downstream outlet. Atmospheric vacuum breakers are for intermittent use only and must never sit under continuous pressure. Freezing climates call for a drain-down plan, since a cracked body is the most common failure on outdoor assemblies.
The 5 Best Backflow Preventers
1. Watts 009M3QT Reduced Pressure Zone Assembly, 3/4 Inch
The Series 009 from Watts is the benchmark residential RPZ, and the 009M3QT is its 3/4 inch version with quarter-turn ball valve shutoffs. Two in-line independent check valves sit on either side of a hydraulically driven relief valve, so a fouled check on either side vents to atmosphere instead of letting contaminated water pass. The body is bronze, the check seats are replaceable, and test cocks are built in for the annual gauge test most utilities demand.
This is the device to choose when the hazard is real: a boiler feed, a chemical dispenser or a service line your water provider flags as high hazard. It handles continuous pressure, works against both backsiphonage and backpressure, and carries the ASSE 1013 listing inspectors look for. Watts publishes a maximum working pressure of 175 psi and a temperature span of 33 to 180 degrees F for the series. Install it with an air gap drain fitting, because the relief port discharges during fouled-check events.
Specs
- Type: Reduced pressure zone assembly (RPZ)
- Size: 3/4 in, NPT connections
- Body material: Bronze
- Maximum working pressure: 175 psi
- Temperature range: 33 to 180°F
- Shutoffs: Quarter-turn ball valves with test cocks
- Listings: ASSE 1013, AWWA C511, CSA B64.4
2. Febco 765EBV Pressure Vacuum Breaker, 1 Inch
For lawn irrigation, the Febco 765 in the 1 inch size is the assembly plumbers reach for first. A pressure vacuum breaker pairs a spring loaded check valve with an air inlet port in one bronze body: when line pressure falls, the check closes and the air port opens to break the siphon before sprinkler water or fertilizer can be drawn back into the house supply. The 765EBV version includes quarter-turn shutoff ball valves and test cocks.
Febco builds the bonnet and poppet from engineered plastic on purpose: in a freeze, the plastic bonnet gives before the bronze body cracks, turning the repair into a cheap part swap instead of a full replacement. The published limits are 150 psi maximum working pressure and a 32 to 140 degree F temperature span. It carries the ASSE 1020 listing. Remember the limits of the type: it guards against backsiphonage only, and it must sit at least 12 inches above the highest sprinkler head downstream.
Specs
- Type: Pressure vacuum breaker (PVB)
- Size: 1 in, NPT connections
- Body material: Bronze
- Maximum working pressure: 150 psi
- Temperature range: 32 to 140°F
- Weight: 5.9 lb
- Listings: ASSE 1020, CAN/CSA B64.1.2
3. Zurn Wilkins 1-350 Double Check Valve Assembly, 1 Inch
Where the hazard is low but a testable device is still required, a double check valve assembly is the usual answer, and the Zurn Wilkins Model 350 in the 1 inch size is a long-running example. Two independently acting check valves in a cast bronze body block reverse flow from both backsiphonage and backpressure, with full port ball valves and test cocks so a tester can verify each check on schedule. There is no relief valve, so nothing discharges during faults, which suits indoor lines where no drain is available.
Zurn publishes a maximum working water pressure of 175 psi, a maximum working temperature of 180 degrees F and a hydrostatic test pressure of 350 psi for the 350 family. The body is cast bronze to ASTM B 584, with threaded end connections to ANSI B1.20.1. The line carries the ASSE 1015 listing, with NSF/ANSI 61 and 372 compliance in the lead free XL versions. Typical duties are service entrances, fire sprinkler feeds without additives, and irrigation zones where backpressure is possible but the water is not a health hazard.
Specs
- Type: Double check valve assembly
- Size: 1 in, threaded connections
- Body material: Cast bronze, ASTM B 584
- Maximum working pressure: 175 psi
- Maximum working temperature: 180°F
- Hydrostatic test pressure: 350 psi
- Listings: ASSE 1015, NSF/ANSI 61, NSF/ANSI 372
4. A.R.I. RP-501 Reduced Pressure Backflow Preventer, 3/4 Inch
The RP-501 from A.R.I. Flow Control takes the RPZ layout and rebuilds it in composite. The body and shutoff valves are molded from glass reinforced nylon instead of bronze, which removes corrosion and scale from the failure list and cuts the 3/4 inch assembly down to 2.6 lb. Inside, two independent spring loaded check valves and a differential relief valve do the same work as a metal RPZ, and all internals come out through one access cover without special tools.
A.R.I. publishes a working pressure of 150 psi and a temperature span of 33 to 110 degrees F, so this is a cold water device; keep it off hot lines. The approval list is complete: ASSE 1013, AWWA C511, NSF 61-G and CSA B64.4, plus USC Foundation approval. Composite construction also removes the theft appeal of scrap bronze. For irrigation manifolds and chemical mixing stations in mild climates, the RP-501 gives full high hazard protection in a body one person can hang on a line alone.
Specs
- Type: Reduced pressure assembly (RPZ)
- Size: 3/4 in, NPT connections
- Body material: Glass reinforced nylon composite
- Working pressure: 150 psi
- Temperature range: 33 to 110°F
- Weight: 2.6 lb
- Listings: ASSE 1013, AWWA C511, NSF 61-G, CSA B64.4
5. Cash Acme V-101 Anti-Siphon Vacuum Breaker, 1/2 Inch
Not every cross-connection needs a full assembly. The Cash Acme V-101 is an atmospheric vacuum breaker for single outlets: a small bronze body with a silicone seat and female threaded connections that screws onto a sillcock, laundry outlet or hose fed fixture and vents the line to atmosphere the moment pressure drops. It is the code recognized guard for hoses left in pools, utility sinks with a hose below the rim, and similar single-point risks.
Cash Acme publishes a maximum intermittent pressure of 125 psi and a maximum temperature of 212 degrees F for the V-101, and the device carries the ASSE 1001 listing. The 1/2 inch FNPT version here uses part number 17383-0000LF. Two limits define the type: it protects against backsiphonage only, and it must never sit under continuous pressure. Within those limits it is a simple device with nothing to test, exactly what a hose connection calls for.
Specs
- Type: Atmospheric vacuum breaker, anti-siphon
- Size: 1/2 in FNPT
- Body material: Bronze with silicone seat
- Maximum pressure: 125 psi, intermittent only
- Maximum temperature: 212°F
- Part number: 17383-0000LF
- Listings: ASSE 1001
Comparison Table
| Device | Type | Size | Max pressure | Best use |
|---|---|---|---|---|
| Watts 009M3QT | RPZ assembly | 3/4 in | 175 psi | High hazard service lines |
| Febco 765EBV | Pressure vacuum breaker | 1 in | 150 psi | Lawn irrigation |
| Zurn Wilkins 1-350 | Double check assembly | 1 in | 175 psi | Low hazard service lines |
| A.R.I. RP-501 | RPZ assembly, composite | 3/4 in | 150 psi | Corrosion prone installs |
| Cash Acme V-101 | Atmospheric vacuum breaker | 1/2 in | 125 psi | Hose and sillcock outlets |
Frequently Asked Questions
Which type of backflow preventer does my home need?
The hazard level at the cross-connection decides the type. Health hazard lines, such as boiler feeds and chemical dispensers, need a reduced pressure zone assembly. Irrigation systems usually take a pressure vacuum breaker or a double check assembly, depending on local code. A single hose outlet needs only an atmospheric vacuum breaker. Confirm the accepted device with your water utility before buying.
Does a backflow preventer need yearly testing?
Testable assemblies, meaning RPZ and double check models with test cocks, need a gauge test by a certified tester every year in most jurisdictions. Vacuum breakers without test cocks are inspected visually instead. Skipping a required test can bring a fine or a shutoff notice from the water provider.
Can a pressure vacuum breaker handle backpressure?
No. A pressure vacuum breaker protects against backsiphonage only, which is reverse flow caused by a pressure drop on the supply side. If downstream pressure can rise above supply pressure, from a pump, an elevated tank or thermal expansion, the accepted choices are a double check assembly for low hazard lines or a reduced pressure zone assembly for health hazard lines.
Where should an RPZ assembly be installed?
Install it indoors or in a protected enclosure where the relief valve discharge can reach a drain through an air gap, with clearance below the port and room on all sides for testing and repair. It must never sit in a pit that can flood, because a submerged relief port defeats the protection.
Why does my RPZ drip water from the relief port?
A brief discharge during pressure swings is normal, because the relief valve holds the zone between the checks at a lower pressure than the supply. A constant drip usually means debris on the first check seat, a worn disc or a fouled relief valve seat. Most assemblies open from one cover, and makers sell rubber parts kits, so a cleaning and kit swap fixes the common causes.
Conclusion
Pick the device by hazard first and brand second. For high hazard lines, the Watts 009M3QT gives the classic bronze RPZ layout with full test hardware, while the A.R.I. RP-501 trades metal for a corrosion proof composite body at a fraction of the weight. The Febco 765EBV remains the irrigation standard, with a bonnet designed to sacrifice itself in a freeze. Where the hazard is low but testing is required, the Zurn Wilkins 1-350 covers the line quietly, and the Cash Acme V-101 handles the hose outlet. Match the listing to your code and size to the line.
FAQ
Which type of backflow preventer does my home need?
Does a backflow preventer need yearly testing?
Can a pressure vacuum breaker handle backpressure?
Where should an RPZ assembly be installed?
Why does my RPZ drip water from the relief port?
More from Amazon
Programs that pair well with the guide above. Offers and eligibility are set by Amazon and may change.
Set up recurring deliveries of everyday items on eligible products. Terms and savings are set by Amazon.
Explore Subscribe & SaveCollect the home and kitchen items you want in one registry that guests can shop from.
Create a wedding registryFree shipping on eligible items, Prime Video and more. Eligible new members can start with a free trial.
Start a Prime free trialAudiobooks and podcasts to listen to on the go. Eligible new members can start with a free trial.
Try Audible freeAs an Amazon Associate we earn from qualifying purchases.